Vue de la page 1
Intellisys Adaptive Pressure Controller
Quick-Start Guide
APC-x00A and APC-x50A series Adaptive Pressure Controllers
Nor-Cal Products, Inc. 1967 South Oregon St., Yreka, CA 96097 USA
LIT-APC-QSG, 12/2004
Power Connections and Valve Cable Connections
* Use only Nor-Cal TBV-CRD Series valve cables.
Analog/TTL
Description
Pin
Power V-
11
Power V+
12
Chassis GRND
25
Auxiliary
Description
Pin
Power V-
5
Power V+
7
Chassis GRND
15
Front
Rear
Rear
AC-Power
Input
Front
AC-Power
Switch
Touch Screen
Display
AC-Power
Input
AC-Power
Switch
Valve Cable*
Connection
Valve Cable*
Connection
Valve Cable*
Connection
V+ V- Gnd
24 VDC (+/- 10%)
4-Amp
Power Supply
(Customer
furnished)
Valve Motor
Valve Cable*
Connector
The APC-x00L-A receives
DC power through the
ANALOG/TTL port or the
AUXILIARY port.